TEST
SPECIFICATION
%
of
Ampere
Rating
|
Openning
Time
|
110%
|
4
hours,
Minimum
|
135%
|
1
hour,
Maximum
|
200%
|
5
sec~2
Minutes
|
UL
File No.E236987
51S/52S
125V 300mA-3.5A(Listed)
4A-8A(Recongnized)
51S/52S
250V 300mA-3.5A(Listed)
4A-8A(Recongnized)
CSA
Certified file No.1433145/1438084
51S/52S
125V 300mA-3.5A(Listed)
4A-8A(Recongnized)
51S/52S
250V 300mA-3.5A(Listed)
4A-8A(Recongnized)
Interrupting
Rating
10,000
amperes at 125V
AC (300mA-3.5A)
|
500
amperes at 125V AC
(4A-8A)
|
35
amperes at 250V AC
(300mA-1A)
|
100
amperes at 250V AC
(1.2A-8A)
|
RATINGS
51S,
52S
Cat.
No
|
Ampere
|
0500 H/L
0600 H/L
0630 H/L
0750 H/L
0800 H/L
010 H/L
013 H/L
015 H/L
016 H/L
020 H/L
025 H/L
030 H/L
032 H/L
035 H/L
040 H/L
050 H/L
060 H/L
063 H/L
070 H/L
080 H/L
|
500mA
600mA
630mA
750mA
800mA
1A
1.25A
1.5A
1.6A
2A
2.5A
3A
3.15A
3.5A
4A
5A
6A
6.3A
7A
8A
|
H denotes for 250V / L denotes for 125V |
TIME-CURRENT
CHARACTERISTICS
|